Receiving error "An error occurred while processing the response"; Corruption

Potential Symptoms

  • Receiving the following alert in Venus: "An error occurred while processing the response", but status is received.
    • May receive a secondary alert such as "Name cannot begin with '0' character, hexadecimal value 0x30. Line2, position 29".
      Error - An error occurred while processing the response.png
  • Unable to send, update, retrieve, or remove content or schedules with Venus software but can connect with M2Config and able to automatically detect the display with no issues.
  • Unable to retrieve status in Venus 1500.
  • May occur with display controllers with no messages sent/stored on it (new controller).
  • May also see the following errors in Venus 1500: Data Access Error: There is insufficient system memory in resource pool "internal" to run this query or There is insufficient system memory in resource pool "internal" to run this query.
  • May see the following error in the Venus 1500 error logs: "Data access error: Duplicate entries not allowed."

Environment

  • Product: AF-3150, AF-3160, AF-3165, AF-3180, AF-3190, AF-3197, AF-3200, AF-3220, AF-3400, AF-3500, AF-3550, AF-3700, Electronic Message Center (EMC) or Board (EMB), Marquee, Readerboard
  • Component: M2 & M3 controller based products
  • Control System: Venus 1500, Version 4

Cause

  • Message, schedule, or memory on the controller is corrupt or unreadable.
    • Messages on the display that have a special character in the name of the message can trigger this alert.
    • The naming scheme may have been ok in V3 but V4 needs an Alphanumeric naming scheme.
    • Issue may be seen more frequent when updating from V3 to V4 software.

Resolution

    1. Follow How do I publish or remove a message or presentations to or from display in Venus 1500 v4, DD2093330.
    2. If the issue returns after republishing content, check the names of all messages being sent to the display and remove special characters from the message names.
    3. After changing the content naming, go back to step 1.

KB ID: DD1990364


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.