Ross XPressions giving checksum error with All Sport CG

​Symptoms

  • XPressions Computer is giving a RX checksum error and/or a Flushing Buffer Error when trying to use an All Sport CG with Ross XPressions.

Environment

  • All Sport CG
  • Ross XPression DataLinq Server

Cause

  • The All Sport CG is outputting revision 2 of the data feed while the XPression software is looking for revision 1.

Resolution

  • For All Sport CG (SD) revision 1 and 2 either:
    • Backdate firmware on All Sport CG to Version 2.5 OR
    • Update Ross XPression software to at least version 5.7 build 3064
  • For All Sport CG (SD) revision 3 and All Sport CG (HD):
    • Update Ross XPression software to at least version 5.7 build 3064
    • There is no way to backdate the revision 3 hardware to the revision 1 output.