Some of the weight classes are not showing up or are missing from being displayed on Stat Panels

Symptom

  • Some of the weight classes are not showing up or are missing from being displayed on stats panels.

Environment

  • SD-2101
  • SD-2102
  • SD-2103
  • SD-2104
  • SD-3101
  • SD-3102
  • SD-3103
  • AS-5000
  • AS-5100 
  • AS-5500

Cause

  • Display lines for weight class is set incorrectly for the model Stat Panel being used.
    • Example: Have 6 position stats panels and the display lines is set to 5.

Resolution

  1. Press Menu.
  2. Use the arrow keys and navigate to Edit Settings and press enter.
  3. Use the arrow keys and navigate to # of Disp Lines.
  4. Press the # key that matches the number of lines on a single Stat Panel cabinet. 
    1. This will be either 5 or 6.
  5. Press enter.
  6. Use the arrow keys to navigate back to # of Disp Lines and verify the line setting is correct.
  7. Press the Menu key and resume operation.

KB ID: DD2174488


Fill out my online form.
DISCLAIMER: Use of this content may void the equipment warranty, please read this DISCLAIMER prior to performing any service of the equipment.