Troubleshooting IDM - Communication Failure Event on Module
Potential Symptoms
-
Communication Failure Event on Module
Environment
- Product Family: Billboard
- Products: AF-2014, DB-1000, DB-2000, DB-3000, DB-4000, DB-4100, DB-4200, DB-5000, DB-6000, DB-6400, DXB-0100, BLD-0100
- Component: PL5x module, power supply, ribbon cable
- Control System: IDM
Resolution
- This issue cannot be addressed remotely.
DB-1000 - DB-3000
- Is module(s) blank?
- If yes, proceed to Step 2.
- If no, skip ahead to Step 8.
- If receiving proper voltage, skip ahead to Step 8.
- If not receiving proper voltage, proceed to Step 3.
- If receiving power, replace power supply output fuse as per Module Blank No Power, Bad Fuse, DD1977765.
- If not receiving power, proceed to Step 4.
- If receiving proper voltage, replace power supply as per Module section or entire display blank, failed power supply, DD1974242.
- If voltage is incorrect, proceed to Step 5.
- If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 6.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 7.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
- If issue follows, resolve as per Row of blank modules, bad module output, DD1988623.
- If issue does not follow, proceed to Step 9.
- If issue follows, replace the module as the issue is within the module. Refer to Blank module(s), communication failure event in IDM, issue follows module, DD2031383 for blank module. For modules with no visual issues, refer to Communication failure module in IDM with no visual issues, DD2588679.
- If issue does not follow, proceed to Step 10.
- If issue follows, replace the module as issue is within the module. Refer to Row of blank modules, bad module output, DD1988623.
- If issue does not follow, contact Daktronics or your service provider for further assistance.
DB-4100
- Is module(s) blank?
- If blank, proceed to Step 2.
- If not blank, power cycle module as per Communication failure module in IDM with no visual issues, DD2588679. If issue persists, skip ahead to Step 6.
- Verify correct voltage is being received at the power supply for the module. (Typically 120 VAC +/- 5%)
- If voltage is correct, skip ahead to Step 6.
- If voltage is incorrect, proceed to Step 3.
- Test voltage at the breaker that supplies power to the affected area/module.
- If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 4.
- Test voltage at the power entrance on the sign.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 5.
- Test voltage at main power entrance to display.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance
- If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
- Is the green indicator light lit on the power supply?
- If lit, proceed to Step 7.
- If not lit, replace power supply as per DB-4100, GP3, module blank, power supply failure, DD2356279.
- Complete a self-test on the module, note error on toe tag and return for repair. Refer to How to perform a self test on a PL5x series module, DD2045934 for instruction.
DB-4200, DB-5000, DB-6000, DB-6400
- Is module(s) blank?
- If blank, proceed to Step 2.
- If not blank, power cycle module as per Communication failure module in IDM with no visual issues, DD2588679. If issue persists, skip ahead to Step 6.
- Verify correct voltage is being received at the power supply for the module. (Typically 120 VAC +/- 5%)
- If voltage is correct, skip ahead to Step 6.
- If voltage is incorrect, proceed to Step 3.
- Test voltage at the breaker that supplies power to the affected area/module.
- If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 4.
- Test voltage at the power entrance on the sign.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 5.
- Test voltage at main power entrance to display.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
- Is the green indicator light lit on the power supply?
- If lit, proceed to Step 7.
- If not lit, replace power supply as per Two modules next to each other blank, Failed power supply, DD2677767.
- Complete a self-test on the module, note error on toe tag and return for repair. Refer to How to perform a self test on a PL5x series module, DD2045934 for instruction.
KB ID: DD3432407
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.
The above disclaimer applies to any property damage, equipment failure, liability, infringement, or personal injury claim arising out of or in any way related to your use or application of the content, whether such claim is for breach of contract, tort, negligence or any other cause of action.