When getting status or clicking Publish to Display Venus 1500 v4 Crashes and gives error "Venus 1500 by Daktronics has encountered a problem and needs to close."

Potential Symptoms

  • When clicking Publish to Display Venus 1500 v4 Crashes and gives error:
    • Venus 1500 by Daktronics has encountered a problem and needs to close.
  • When getting status of display Venus 1500 V4 crashes and gives error:
    • Venus 1500 by Daktronics has encountered a problem and needs to close.
  • When viewing Venus1500.log view the following error:
    • Error Message: Data Access Error: Duplicate entries not allowed.
  • To view error log above, follow directions:
    1. Go to your Computer or My Computer and navigate to the following location:
      1. Windows XP - C:\Documents and Settings\All Users\Application Data\Daktronics\Venus 1500 v4
      2. Windows Vista or 7 - C:\ProgramData\DAKTRONICS\Venus 1500 V4
    2. Open the Venus1500.log by right-click -> Open With -> Notepad.
    3. Scroll down to the last few error entrees and look for the above error.

Environment

  • Product Family: Software
  • Product: Venus 1500
  • Component: Venus 1500 Version 4
  • Control System:

Cause

  • The configured display(s) in the Nucleus Database are corrupted.

Resolution

  • IMPORTANT: Please follow directions step by step. Failing to follow directions may cause lost information.
  1. Launch Venus 1500 v4.
  2. Click the Orange V Application Menu -> Configure -> Displays.
  3. Select the Display(s) and click Edit.
  4. Write down or make a note of the Sign Configuration and communication type information.
    1. Repeat if multiple displays.
  5. Select the Display(s) and click Remove Display.
  6. On the prompt "Are you sure you wish to permanently delete the display?" Click Yes.
    • IMPORTANT, on the second prompt "Would you like to remove all content associated with this display, including presentation, schedules, and backups?" Click No
      • If you click Yes to this prompt you will lose ALL created presentations and schedules. 
      • If you click Yes to this prompt those presentations are permanently deleted and cannot be restored by Daktronics.
  7. Re-Configure the Display(s) by following How do I create and configure a new display in Venus 1500 v4? DD1974222 and using the information that was written down or noted about the configuration.

For Temporary Operation

KB ID: DD2358784


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.