How to configure a new VLink/VIP 4400 using the initialize script

Potential Symptoms

  • Configure a new VLink/VIP 4400 by using the initialize script on the Venus 7000

Environment

  • Product: DMP-7000 or Display Studio
  • Components: DMP-7000 (Venus 7000, VIP-4400, VIP-4500, VIP-4060 (DD 4042)
  • Control System: Venus Control Suite Daktronics Hosted

Resolution

From the Venus 7000 (DMP-7000)

Prerequisites: The Initialize button must be configured, reference the Venus 7000: How do I create an initialize button article

  1. In the Venus 7000 Shell, click on the Display button to open the V7Display - Scripting page
  2. Click on the Initialize button to run the initialize script, this will send the default configuration to the VLink's
  3. In the little window below the script buttons you will see the results of the Initialize script commands, quickly verify that all lines have an OK: and that the last line reads "Script has ended"
  4. Go to the Start button>All Programs>Venus 7000> Venus 7000 Tools> and open the V7 VLink Debug program
  5. Click on the sign drop-down and select the newly installed VLink
  6. Select channel drop down-channel #1
  7. In the command field, type "cf s" and click the send command button, this will store the current configuration onto the VLink so that it will load automatically each time the VLink boots up
    • Repeat steps 6 and 7 for any remaining channels that were configured.

From Display Studio

Prerequisites: The Initialize button must be configured. 

  1. Click on the Initialize button to run the initialize script, this will send the default configuration to the VLink's.
  2. In the little window above the script buttons you will see the results of the Initialize script commands, quickly verify that all lines have an OK: and that the last line reads "Script has ended".
  3. In the Venus 7000.
    1. Go to the Start button>All Programs>Venus 7000> Venus 7000 Tools> and open the V7 VLink Debug program.
    2. Click on the sign drop-down and select the newly installed VLink.
    3. Select channel drop down-channel #1.
    4. In the command field, type "cf s" and click the send command button, this will store the current configuration onto the VLink so that it will load automatically each time the VLink boots up.
    5. Repeat steps 6 and 7 for any remaining channels that were configured.

KB ID: DD2255362


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.