How to start a test pattern on an MLC 405x
Potential Symptoms
How to start a test pattern on an MLC 405x?
Environment
- Product Family: Message Displays
- Product: AF-3500
- Component: MLC 405x
- Control System: Venus 1500, Display Studio
Resolution
- MLC405x microcontroller revision 35 and later supports DIP switch lockout. This feature was implemented to prevent a faulty DIP switch from running module test patterns.
- On the S2 switch of the MLC the switches are numbered from bottom to top 1 thru 4.
- Run the following sequence in 10 seconds or less
- Switch DIP #1 up
- Switch DIP #4 up
- Switch DIP #1 down
- Switch DIP #4 down
- If the sequence is input correctly, the test patterns are unlocked and DS3 (MLC4051) illuminates.
Table S2 | |||||
Switch 4 | Switch 3 | Switch 2 | Switch 1 | Switch Value | Mode |
Down | Down | Down | Down | 0 | Normal Operation |
Down | Down | Down | Up | 1 | Scrolling Colors (Test Pattern) |
Down | Down | Up | Down | 2 | Red (Test Pattern) |
Down | Down | Up | Up | 3 | Green (Test Pattern) |
Down | Up | Down | Down | 4 | Blue (Test Pattern) |
Down | Up | Down | Up | 5 | White (Test Pattern) |
Down | Up | Up | Down | 6 | Display Stored Content (1) |
Down | Up | Up | Up | 7 | Normal Operation (2) |
Up | Down | Down | Down | 8 | Normal Operation (2) |
Up | Down | Down | Up | 9 | Normal Operation (2) |
Up | Down | Up | Down | A | Normal Operation (2) |
Up | Down | Up | Up | B | Normal Operation (2) |
Up | Up | Down | Down | C | Normal Operation (2) |
Up | Up | Down | Up | D | Normal Operation (2) |
Up | Up | Up | Down | E | Normal Operation (2) |
Up | Up | Up | Up | F | Self Test (3) |
(1) Micro revision 3D and newer supports this feature. Older revisions show scrolling colors.
(2) Micro revision 3E and newer supports this feature. Older revisions show scrolling colors.
KB ID: DD2064850
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.
The above disclaimer applies to any property damage, equipment failure, liability, infringement, or personal injury claim arising out of or in any way related to your use or application of the content, whether such claim is for breach of contract, tort, negligence or any other cause of action.