How to start a test pattern on an MLC 405x

Potential Symptoms

How to start a test pattern on an MLC 405x?

Environment

  • Product Family: Message Displays
  • Product: AF-3500
  • Component: MLC 405x
  • Control System: Venus 1500, Display Studio

Resolution

  • MLC405x microcontroller revision 35 and later supports DIP switch lockout.  This feature was implemented to prevent a faulty DIP switch from running module test patterns.
  • On the S2 switch of the MLC the switches are numbered from bottom to top 1 thru 4.
  1. Run the following sequence in 10 seconds or less
    1. Switch DIP #1 up
    2. Switch DIP #4 up
    3. Switch DIP #1 down
    4. Switch DIP #4 down
  2. If the sequence is input correctly, the test patterns are unlocked and DS3 (MLC4051) illuminates.
Test patterns remain unlocked as long as at least one DIP switch is up.  After all DIP switches are down, the MLC waits 10 seconds before locking test pattern. 
 
 Table S2
 Switch 4 Switch 3 Switch 2 Switch 1 Switch Value Mode 
 Down Down Down Down 0 Normal Operation 
 Down Down Down Up 1 Scrolling Colors (Test Pattern)
 Down  Down Up Down 2 Red (Test Pattern)
 Down Down Up Up 3 Green (Test Pattern)
 Down Up Down Down 4 Blue (Test Pattern)
 Down Up Down Up 5 White (Test Pattern)
 Down Up Up Down 6 Display Stored Content (1)
 Down Up Up Up 7 Normal Operation (2)
 Up Down Down Down 8 Normal Operation (2)
 Up Down Down Up 9 Normal Operation (2)
 Up Down Up Down A Normal Operation (2)
 Up Down Up Up B Normal Operation (2)
 Up Up Down Down C Normal Operation (2)
 Up Up Down Up D Normal Operation (2)
 Up Up Up Down E Normal Operation (2)
 Up Up Up Up F Self Test (3)

(1) Micro revision 3D and newer supports this feature.  Older revisions show scrolling colors. 
(2) Micro revision 3E and newer supports this feature.  Older revisions show scrolling colors.

KB ID: DD2064850


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.