How do I display a test pattern for in displays using a Nova LCT-Mars Sender Box?

Topic

  • How to display a test pattern for in displays using a Nova LCT-Mars Sender Box?

Environment

  • Product Family: Sender Box
  • Product: Nova MCTRL 600, Nova MCTRL 660, NovaStar VX4S, NovaStar brand sender box and receiver  cards
  • Components: NovaLCT-Mars, Monitoring/ Status Checks
  • Control System: Market Standard or Limited Compliance using transmit common/open protocol
    • This includes but not limited to DVN-4003, Dragon Sticks, J Series, JVX, NPN-4200/4400, NPN-5200/ 5400, U Series, Q Series, QVN, Z Series, and ZPN.

Steps

  1. Launch the  NovaLCT-Mars to enter Screen Config. configuration program.
  2. Click on the Screen Control tile.
  3. Choose the test pattern from the drop down.
    • Kill/ Black out --- Show nothing on the LED display.
    • Lock/Freeze --- Always show the current image frame of the LED display.
    • Run/Normal --- Switch the LED display back to normal from Kill or Lock.
    • Self Test --- show the test images generated by the receiver card for LED displays aging test or error detecting.
  4. Choose send to play the test. 
    test patterns.png
  5. To return to regular operation, choose Normal and Send.