Environment
- Product Family: Billboard
- Products: AF-2014, DB-1000, DB-2000, DB-3000, DB-4000, DB-4100, DB-4200, DB-5000, DB-6000, DB-6400, DXB-0100, BLD-0100
- Component: PL5x module, power supply, ribbon cable
- Control System: IDM
Troubleshooting Steps
Remote Troubleshooting Steps
- This issue cannot be addressed remotely.
Onsite Troubleshooting Steps
DB-1000 - DB-3000
- Is module(s) blank?
- If yes, proceed to Step 2.
- If no, skip ahead to Step 8.
- If receiving proper voltage, skip ahead to Step 8.
- If not receiving proper voltage, proceed to Step 3.
- If not receiving power, proceed to Step 4.
- If voltage is incorrect, proceed to Step 5.
- If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 6.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 7.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
- If issue follows, resolve as per Row of blank modules, bad module output, DD1988623.
- If issue does not follow, proceed to Step 9.
- If issue does not follow, proceed to Step 10.
- If issue does not follow, contact Daktronics or your service provider for further assistance.
DB-4100
- Is module(s) blank?
- Verify correct voltage is being received at the power supply for the module. (Typically 120 VAC +/- 5%)
- If voltage is correct, skip ahead to Step 6.
- If voltage is incorrect, proceed to Step 3.
- Test voltage at the breaker that supplies power to the affected area/module.
- If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 4.
- Test voltage at the power entrance on the sign.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 5.
- Test voltage at main power entrance to display.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance
- If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
- Is the green indicator light lit on the power supply?
- Complete a self-test on the module, note error on toe tag and return for repair. Refer to How to perform a self test on a PL5x series module, DD2045934 for instruction.
DB-4200, DB-5000, DB-6000, DB-6400
- Is module(s) blank?
- Verify correct voltage is being received at the power supply for the module. (Typically 120 VAC +/- 5%)
- If voltage is correct, skip ahead to Step 6.
- If voltage is incorrect, proceed to Step 3.
- Test voltage at the breaker that supplies power to the affected area/module.
- If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 4.
- Test voltage at the power entrance on the sign.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, proceed to Step 5.
- Test voltage at main power entrance to display.
- If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance.
- If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
- Is the green indicator light lit on the power supply?
- Complete a self-test on the module, note error on toe tag and return for repair. Refer to How to perform a self test on a PL5x series module, DD2045934 for instruction.