Galaxy: How do I configure the standard settings for Commercial Galaxy Displays in M2Config?

Topic

  • How do I configure the standard settings for Commercial Galaxy Displays in M2Config?

Environment

  • Product Family: Message Displays
  • Product: Galaxy, AF-3200, AF-3220, AF-3400, AF-3700, AF-3500, AF-3550, Electronic Message Center (EMC), Marquee, Electronic Message Board (EMB)
  • Component: M2Config Utility Software, M2 or M3 controllers
  • Control System:

Steps

Warning: Misuse of this utility can render your sign inoperable.

👉 If a setting is not listed below, it can generally be overlooked as the default setting is acceptable.

Step 1: Install M2Config: Galaxy: How do I download & install the M2Config Utility on my computer?

Step 2: Connect to the display using M2Config:  Galaxy: How do I connect to my Galaxy display using the M2Config Utility?

Step 3: Use M2Config to set the standard settings on the following display types.

M2Config Settings - Display Types

AF-3200-

12mm

AF-3200-34mmAF-3220-34mmAF-3400-20mmAF-3400-34mmAF-3400-46mmAF-3700-20mmAF-3700-34mmAF-3500-20mmAF-3500-34mmAF-3500-46mmAF-3500-DF-20mmAF-3550-16mm
Product FamilyGalaxyGalaxyGalaxyGalaxyGalaxyGalaxyGalaxy ProGalaxy ProGalaxyGalaxyGalaxyGalaxyGalaxy
Module Size16x168x88x816x168x88x816x168x816x168x88x816x1616x16
Color Depth

Mono

 

Mono 64 or RGB 32,768Mono 64 or RGB 32,768Mono 64 or RGB 32,768Mono 64 or RGB 32,768Mono 64 or RGB 32,768RGB 16,777,216RGB 16,777,216Mono 4096 or RGB 68 BillionMono 4096 or RGB 68 BillionMono 4096 or RGB 68 BillionMono 4096 or RGB 68 BillionMono 4096 or RGB 68 Billion
Module Type
Note: Color Depth & Product family will need to be set before Module Type.
AF-6120 12mm 16 highAF-3200 34mmAF-3220AF-3400 20mmAF-3400 34mmAF-3400 46mmAF-3700
AF-3700
with MLCs
AF-3500AF-3500AF-3500
AF-3500
Double Face
AF-3500
Number of Faces11111111,21,2,3,41,2,3,41,2,3,4Double Face1,2,3,4
              
Gamma2.22.22.22.22.22.22.22.22.52.52.52.52.5
Refresh Rate120120120120120120120120120120120120120
Dimming Level

high 100

low 6

high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
high 100
low 6
Temperature - High65656565656570707070707070
Temperature - Low55555555555560606060606060
              
Max Log File Size100,000100,000100,000100,000100,000100,000100,000100,000100,000100,000100,000100,000100,000
              
Version 1 File Storage - StandardUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storageUse volatile storage
              
Multiplier - Serial11111111NANANANANA
Multiplier - Ethernet *128128128128128128128128128128128128128

Step 4: Click File -> Set Configuration if any changes are made within M2Config.. (Sign will reset)

Note: If a display is utilizing a Lantronix device or Ethernet to Serial device the Multiplier needs to be set to 1.

Note * - A standard multiplier setting of 128 will generally work on most Ethernet systems. If issues are experienced when connecting to or publishing content to a display, the multiplier can be adjusted anywhere from 1 to 128. Generally a lower multiplier (1, 5, 16) ensures content transfer.

KB ID: DD2241913


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.

The above disclaimer applies to any property damage, equipment failure, liability, infringement, or personal injury claim arising out of or in any way related to your use or application of the content, whether such claim is for breach of contract, tort, negligence or any other cause of action.