Venus 7000: How do I set up V7000 TXD Output
Topic
- How to set up V7000 TXD Output?
Environment
- Product Family: DMP-7000
- Product: DMP-7000
- Components: DMP-7000 V7000
- Control System: DMP-7000
Steps
- In the Venus 7000 Shell, clink on the Configure Button.
- Click on the TXD Outputs Tab.
- Select an output that does not have anything assigned to it currently. Double click in the white space, or click Edit Output to open up the Edit TXD Output window.
Give the output an appropriate name, and select the following communication properties:
- Output Type:
- Com Port - RS232 Serial Communications (commonly used)
- IPX Socket - Type of Internet Protocol (Not Used)
- RTD Input - Used to send data on the same port as an RTD input
- UDP/IP Socket - Type of Internet Protocol (commonly used)
- TCP/IP Socket - Type of Internet Protocol (Not Used)
- Port: Select appropriate port
- Baud Rate - Baud Rate of the Device being sent to using a Com Port
- Parity - Parity for the Device being sent to using a Com Port
- Data Bits - Data Bits of the Device being sent to Using a Com Port
- Protocol - Protocol for the Device being sent to Using a Com Port
- None - No Protocol
- Sound Burst - Protocol for Sound Burst
- Standard RTD - Protocol for some 3rd party devices
- Enhanced RTD - Protocol for most Daktronics Devices
- CR LF - Protocol for some 3rd party devices
- Broadcast Type - Some of the Output types will have the following options
- Broadcast - Sends data to everything to entire network
- Local - Sends data back to the same machine.
- Other - Allows for Custom IP or range of IPs to be sent on
-
Click "OK" to save the output configuration.
-
Click OK to exit Configuration tab, Sign service will need to be restarted
KB ID: DD3847577
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.