Is it possible to mix & match serial and Ethernet based communication on an OmniSport 2000 console?
Topic
- Can I use any combination of Serial and Ethernet communication for Pro Software and Hy-Tek Results Software
- OmniSport 2000 Expansion Port (J4) Serial for Pro Software / OmniSport 2000 Results Port (J6) Serial for Hy-Tek Results Software.
- OmniSport 2000 Expansion Port (J4) Serial for Pro Software / OmniSport 2000 Ethernet for Hy-Tek Results Software.
- OmniSport 2000 Ethernet for Pro Software / OmniSport 2000 Results Port (J6) Serial for Hy-Tek Results Software.
- OmniSport 2000 Ethernet for Pro Software / OmniSport 2000 Ethernet for Hy-Tek Results Software.
Environment
-
Product Family: Timing
-
Product: Aquatics
-
Component: Hy-Tek Meet Manager v5.0 or higher supports Ethernet
-
Control System: OmniSport 2000e (Ethernet), Pro Software; OmniSport 2000 PRO Swimming, Pro Dive
Steps
-
Note: Do the following steps in swimming mode to make the change for both swimming and diving modes.
- OmniSport 2000 Expansion Port (J4) Serial for Pro Software / OmniSport 2000 Results Port (J6) Serial for Hy-Tek Results Software.
- From
Main Menu - [4]>[7]>[7]
- Use [-->] right arrow to toggle NETWORK PRO: OFF and then press
[ENTER] to continue.
- Use [-->] right arrow to toggle NETWORK MMR: OFF and then press
[ENTER] to save.
- OmniSport 2000 Expansion Port (J4) Serial for Pro Software / OmniSport 2000 Ethernet for Hy-Tek Results Software.
- From
Main Menu - [4]>[7]>[7]
- Use [-->] right arrow to toggle NETWORK PRO: OFF and then press
[ENTER] to continue.
- Use [-->] right arrow to toggle NETWORK MMR: ON and then press
[ENTER] to save.
- OmniSport 2000 Ethernet for Pro Software / OmniSport 2000 Results Port (J6) Serial for Hy-Tek Results Software.
- From
Main Menu - [4]>[7]>[7]
- Use [-->] right arrow to toggle NETWORK PRO: ON and then press
[ENTER] to continue.
- Use [-->] right arrow to toggle NETWORK MMR: OFF and then press
[ENTER] to save.
- OmniSport 2000 Ethernet for Pro Software / OmniSport 2000 Ethernet for Hy-Tek Results Software.
- From
Main Menu - [4]>[7]>[7]
- Use [-->] right arrow to toggle NETWORK PRO: ON and then press
[ENTER] to continue.
- Use [-->] right arrow to toggle NETWORK MMR: ON and then press
[ENTER] to save.
KB ID: DD2916952
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.