Handheld controller screen blank, Incorrect contrast settings.
Potential Symptoms
- RC-100/RC-200 appears to not be turning on.
- RC-100 or FLR-500 screen is blank or very difficult to see.
- RC-100 or FLR-500 handheld buttons are still beeping, but screen is blank.
- RC-100 or FLR-500 handheld buttons are beeping, but screen just has black/dark bar going across screen.
Environment
- Product Family: Sports Product, Digit and Price Displays
- Product: Scoreboard (LED), Gas Price Display
- Component:
- Control System: RC-100 handheld, FLR-500 handheld
Cause
- Contrast is set all the way down (blank screen), or all the way up (dark bar).
- LCD monitor on handheld has failed.
Note: When powering off the handheld (holding On/Off button for 5 seconds), if the display is blank, there should be a line that flashes on the screen which may indicate screen is still functioning. If no line flashes on the screen, then the LCD monitor may be bad.
Resolution
- Replace with an RC-100 handheld with firmware version 3.1.
Note: The changes in this version set a maximum and minimum LCD contrast so the screen cannot be set too dark or too light. The set contrast menu also displays the current contrast level as a number from zero - to the maximum (0A-1110-0053=max 38; 0A-1110-0033=max 23).
For Temporary Operation
Note: It will be hard to determine if the handheld is connecting to the base station since no information can be examined on handheld. However, if one can see the diagnostic LEDs on the server radio receiver base station, the Amber IN RANGE light should be lit.
Directions If Handheld Is Connecting to Board
- Start with the handheld off (buttons shouldn't beep); if buttons are beeping hold the On/Off button for 5 seconds and then wait 10 seconds.
- Press On to power on the handheld.
- Allow time for it to connect to the base station (about 10 seconds).
- Press and hold Config for about 5 seconds.
- Press the Down Arrow once.
- Press Enter.
- Screen blank: Press the Up Arrow repeatedly to increase the contrast until you can see the screen again.
- Screen has dark bar: Press the Down Arrow repeatedly to lower the contrast until good character definition.
- Press Enter to confirm settings.
- If this does not fix the issue, RC-100 LCD monitor has failed and the controller will need to be replaced.
Directions if Handheld Is Not Connecting to Board (Two possibilities)
Instruction Set 1
- Start with the handheld off (buttons shouldn't beep); if buttons are beeping hold the On/Off button for 5 seconds and then wait 10 seconds.
- Press On to power on the handheld.
- Allow time for the handheld to timeout while it tries to connect to the board (~20-30 seconds).
- Press the Clear/No (On/Off) button three times.
- Press the Down Arrow once.
- Press Enter.
- Screen blank: Press the Up Arrow repeatedly to increase the contrast until you can see the screen again.
- Screen has dark bar: Press the Down Arrow repeatedly to lower the contrast until good character definition.
- Press Enter to confirm settings.
Instruction Set 2
- Start with the handheld off (buttons shouldn't beep); if buttons are beeping hold the On/Off button for 5 seconds and then wait 10 seconds.
- Press On to power on the handheld.
- The handheld may not try to connect to board (occurs when channel is set to 00); only takes approximately 10 seconds for the handheld to power on.
- Press the Down Arrow once.
- Press Enter.
- Screen blank: Press the Up Arrow repeatedly to increase the contrast until you can see the screen again.
- Screen has dark bar: Press the Down Arrow repeatedly to lower the contrast until good character definition.
- Press Enter to confirm settings.
KB ID: DD2288857
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.