Receiving "Nucleus Service not running. Nucleus server failed to load", Computer security issue.
Potential Symptoms
- Receiving "Nucleus Service not running. Nucleus server failed to load" when launching Venus 1500
- Nucleus Starts or restarts and appears started, but still receiving error.
- Nucleus Server not being started error and prompted for a username and password.
- Venus 1500 takes a long time for the software to finally launch.
- When launching Content Studio, it suddenly takes longer then normal.
- When adding presentations to the Playlist, it takes over a minute for the list of presentations to load.
- Nucleus errors log will show "Proxy Access Denied"
Environment
- Product Family: Software
- Product:
- Component: Daktronics Nucleus Server
- Control System: Venus 1500 v4
Cause
- If you restart the services, and/or just powered on the computer, it can take up to 20 minutes before you can launch the software successfully. This is caused by a computer security issue, not an issue with the Venus 1500 v4 Software.
Resolution
- Confirm issue via the following steps to ensure proper troubleshooting approach.
- Go to Windows Start Menu, click on Computer or My Computer.
- Go to the following location:
- Windows 32 Bit - C:\Program Files\Daktronics\Nucleus Server\Logs
- Windows 64 Bit - C:\Program Files (x86)\Daktronics\Nucleus Server\Logs
- Open System.log and scroll towards the bottom of log file.
- Do you see a timestamp every 30 seconds or more?
- Yes - Contact Daktronics Technical Support for assistance.
- Some time stamps may show 5-6 at the same time, and then show several minutes between the next set of events.
- One good way to test issue, is stop the Nucleus Server, Rename the Error.log and System.log and start the service. This will generate a clean/fresh log, you can count the minutes or seconds between the first time stamp in the system log, to the final time stamp saying Nucleus Server Successfully started.
- This is a sample, of how the time stamps would or could appear.
- No - Continue troubleshooting with other KB Articles.
KB ID: DD2263557
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.