Receiving an Alert "There was an error reading from the pipe: Unrecognized error 109 (0x6d)" when launching Venus 1500 v4 or when the software connects to display
Potential Symptoms
- Receiving one of the three following alerts when launching Venus 1500 v4 or when the software connects to display:
- Alert 1: There was an error reading from the pipe: Unrecognized error 109 (0x6d)
- Alert 2: There was no endpoint listening at net.pipe://localhost/Daktronics/Nucleus/V1500OperationService that could accept the message. This is often caused by an incorrect address or SOAP action. See InnerException, if present, for more details.
- Alert 3: There was an error reading from the pipe: The pipe has been ended. (109, 0x6d).
- Venus 1500 v4 Crashes when trying to click anything in the software or crashes on initial launch and is accompanied by the following error:
- Venus 1500 has encountered a problem and needs to close. We are sorry for the inconvenience.
Environment
- Product Family: Software
- Product: Venus 1500 V4
- Component:
- Control System: Venus 1500 V4
Cause
- Corrupt Venus installation.
Resolution
Step 1: Delete all .exe.config files.
- Go to Windows Start Menu -> My Computer/Computer.
- Navigate to the following location:
- 32 Bit - C:/Program Files/Daktronics
- 64 Bit - C:/Program Files (x86)/Daktronics
- Locate the following files in each folder and delete them.
- Nucleus Server Folder - nucleus.exe.config
- Venus 1500 v4 Folder - venus1500.exe.config
- Venus 1500 v4 Folder - mediakit.exe.congfig
- Content Studio Folder - contentstudio.exe.config
Step 2: Run a repair on Venus 1500 v4 software.
- Follow DD2387771 on how to run a software repair.
Step 3: Launch Venus 1500 and use software as needed.
KB ID: DD2129694
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.