Error "Could not find file..."; Corrupt database

Potential Symptoms

  • Unable to edit previously created presentations.
  • Unable to create new presentations or publish them to display.
  • When trying to open message, get error:
    • When trying to open old messages in content studio, you get error: The file could not be opened from server.
  • When trying to Publish presentations to the display, receive alert:
    • Windows XP: Could not find file 'C:\Documents and Settings\All Users\Application Data\Daktronics\Nucleus Server\Disk Data\
    • Windows Vista, 7, 8 or 10:  Could not find file 'C:\ProgramData\Daktronics\Nucleus Server\Disk Data\

Environment

  • Product Family: Software
  • Product:
  • Component: Venus Database
  • Control System: Venus 1500 v4

Cause

  • Incorrectly backed up or corrupted database.

Resolution

  • Option 1: If there is still access and boot the old computer, you can copy the database from old PC and reload it to the new PC by using the Nucleus Database Utility. For Venus 1500 v4 follow How do I use the Nucleus Server Database utility to transfer or save a database? DD1705994.
  • Option 2: If you cannot boot the old computer but can still navigate the Hard Drive, you can see if there is an automatic backup file of the old computer database.
    • On the old computer, go to the following location to locate the backup database:
      • Windows 32 Bit System: C:\Program Files\Daktronics\Nucleus Server\Backup
      • Windows 64 Bit System: C:\Program Files (x86)\Daktronics\Nucleus Server\Backup
    • Copy the Backup.nucback file to the New Computer Desktop.
    • Follow one of the two articles in Option 1, on how to copy and transfer a database.
  • Option 3: If there is not a transferred or backed up database, a new database will need to be created using the Nucleus Database Utility.

KB ID: DD2048524


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.