Venus 1500 v4 application hangs or gives Nucleus error when launching; Antivirus blocking services
Potential Symptoms
- When attempting to launch Venus 1500 v4, the splash screen just seems to hang, does not launch and does not prompt for credentials or show any errors.
- When trying to launch Venus 1500 v4, receive Nucleus Error and Username and Password Prompt.
- Launching Venus 1500 v4 and receive error: "The SQL Server (NUCLEUS) service is not running Please try restarting this machine or running as administrator."
- When entering in Default Username and Password, received the following error(s):
- An error occurred while logging in: credential store is not accessible. Ensure that the SQL Server (NUCLEUS) service is running.
- Nucleus Services is not Running. Nucleus Service has failed to load.
- When checking services, all services show running.
- When checking Nucleus Server Error.log, see the following possible errors:
- A TCP error (10013: An attempt was made to access a socket in a way forbidden by its access permissions) occurred while listening on IP Endpoint=0.0.0.0:9245.
- Title: Error during setup of users and roles.
Message: Unable to connect to the remote server.
Unable to connected to the remote server ---> System.Net.Sockets.SocketException: The requested address is not valid in its context [2001:0:9d38:953c:34ca:399:3F57:fed6]:8811
- Fusion Service will not start properly and see the following error in Fusion Event Logs.
-
An unexpected socket exception occurred when sending data. See inner exception for details. A socket operation was attempted to an unreachable host.
-
Could not find the local Fusion service.
Environment
- Product Family: Software
- Product: Venus 1500 v4.22
- Component: Daktronics Nucleus Server service, Anti-Virus Software Firewall (McAfee, AVG, Norton 360, Symantec, Windows Essentials, PANDA, Security Manager AV Defender, N-able Technologies, Sophos Protection, etc.)
- Control System: Venus 1500 v4
Cause
-
An antivirus or firewall program is blocking Venus services from starting properly.
- Note: If they mention they are using Threatlocker see KB 000028882
Resolution
NOTE: this can be accomplished in most cases by adding exceptions in the antivirus for the Daktronics folder in the C:/Program Files and C:/ProgramData directories
- Follow the Anti-Virus Manufacturer Help Guide for assistance, the instructions are different based on brand and version.
- Firewall may need to be turned off during the use of Venus 1500, even with exceptions made.
- For a list of ports Venus 1500 V4 uses, see article: What are the Venus 1500 v4 System Default Ports? DD2509428
Note: In some cases, McAfee Anti-Virus has had to be removed from a computer completely. The Fusion Server, sometimes even with full access granted, still is blocked and this prevented the use of the Venus 1500 software. For a list of suggested Antivirus Clients see article: What antivirus software is recommended or supported on Daktronics supplied computers? DD2079868
For Temporary Operation
- Set Venus to run as Administrator.
KB ID: 000007797
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.
The above disclaimer applies to any property damage, equipment failure, liability, infringement, or personal injury claim arising out of or in any way related to your use or application of the content, whether such claim is for breach of contract, tort, negligence or any other cause of action.