SmartLink offline and power cycle did not resolve, loose mezz card

Potential Symptoms

  • SmartLink showing offline after power cycle & the Radio status LED & Status LED are blinking properly.
  • SmartLink can see a partial signal.

Environment

  • Product: DB-4200, DB-5000, DB-6000, DXB-0100
  • Component: SmartLink
  • Control System:

Cause

  • Mezz card is not seated properly.

Resolution

  • Reseat the mezz card.
    1. In the power entrance box turn off breaker labeled CB3
      • When that breaker is turned off it will take the SmartLink at least 3 minutes to completely discharge, watch the lights on the SmartLink to verify that they do go out.
    2. The three standoffs supporting the mezz card will need to be pressed to unlock them.
    3. Double check that none of the card connectors are bent.
    4. When reseating the card make sure that the top two connectors are not plugged into the SmartLink board. See image below.
    5. Make sure to press firmly on the card to seat it properly.
    6. Restore power to the SmartLink and verify connection.

SL Pins.png

 

KB ID: DD2629074


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.