When installing Venus 1500 V4: 'The setup was unable to automatically close all requested application.', Corrupt .NET framework.

Potential Symptoms

  • When installing Venus 1500 v4 the software gives error 'The setup was unable to automatically close all requested application.' when trying to stop the Daktronics Nucleus Server service. Or when manually trying to stop the Daktronics Nucleus Server you receive error 1053.
  • Error During Installation, causes rollback:Venus 1500 V4 Installer Information: The Setup was unable to automatically close all requested application. Please ensure that the applications holding files in use are closed before continuing with the installation.
  • Error when trying to manually stop the Daktronics Nucleus Server:
    Windows could not stop the Daktronics Nucleus Server service on Local Computer.  Error 1053: The service did not respond to the start or control request in a timely fashion.

Environment

  • Product Family: Software
  • Product:
  • Component: .Net Framework
  • Control System: Venus 1500 v4

Cause

  • The Microsoft .NET Framework is corrupted.

Resolution

KB ID: DD2301891


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.

The above disclaimer applies to any property damage, equipment failure, liability, infringement, or personal injury claim arising out of or in any way related to your use or application of the content, whether such claim is for breach of contract, tort, negligence or any other cause of action.