Cause

  • A maximum of 9 judges can be plugged into either J14 or J15 on the Omni Sport 2000.
  • Can do as many judges consoles on each J14 or J15 as needed as long as there are no more than 9 on one.
    • For example # of judges is set to 5:
      • Could have 4 judges consoles on J14's base station receiver.
      • Could have 1 judge console on J15's base station receiver.
      • (This could be necessary if you have both RC-100 handhelds and RC-200 handhelds)

Resolution

How to setup judges controllers on one Omni 2000? (One or two panels of judges can score a synchronized swimming event.)

  • If there is one panel of judges the judge numbers on the consoles are entered as one through the number of judges configured for the event.
    • When there is one panel of judges, all judges are responsible for entering both sets of scores for the routine.
  • If there are two panels of judges, the second panel would be entered as the next set of judge numbers available after the first panel. 
    • Ex. If there are two panels of five judges, the first panel is entered as judge numbers 1-5 and the second panel is entered as judge numbers 6-10.
    • Up to 18 RC-100/RC-200 controllers can be used at once (9 RC-100/RC-200 controllers per base station)
    • Channels 1-15 can be used, however, the two base stations must be set to different channels.  Each base station and its respective RC-100/RC-200 controllers need to be set to the same channel.
    • When there are two panels of judges the first panel enters the first set of scores and the second panel enters the second set of scores for the routine.

KB ID: DD2180056


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.