How should line to line cables be hooked up when using an Access Port Kit (Outdoor J-Box/Surge Card) for communication at the base of a gas price display?

Question

  • How should line to line cables be hooked up when using an Access Port Kit (Outdoor J-Box/Surge Card) for communication at the base of a gas price display?

Environment

  • Product Family: Digit and Price Displays
  • Product: FL-3000, FL-4500
  • Components: Line to line cable, Driver, Outdoor J-Box
  • Control System:

Answer/Steps

  1. Line to line cables would still be hooked up the standard way through all gas price displays.  Keep in mind that if you are tracing communications from the Access Port  (Outdoor J-Box) which hooks into the last driver in line, that the line to line cable would start in J10 on that driver and go to J9 and so on back to the "host" driver where the "Main" communications method is coming into.
  2. The following can be reference for How should line to line cables be installed in a FL-3000 gas price display system.

KB ID: DD4111110


Fill out my online form.