GP4/DB-4200 is dim, Time Out Occurrence when trying to log into VIP-5060 web interface

Potential Symptoms

  • Unable to log into the VIP 5060 web interface but can ping it.
    • Receive a "Failed to Connect" error/alert stating "the device is not responding" when trying to log into VIP.
    • Receive timeout error after entering the username and password to log into the VIP-5060.
    • VIP shows "Communication Failure" event in IDM. 
  • Display is in a fully dim or bright state and is not responding to manual or automatic brightness commands.
    • When trying to change the brightness mode in the DMP-8000 web interface, may receive the following: "An error has occurred while updating the configuration connection failed
    • GP4: If Venus controlled the brightness setting will show: "Schedule [0]: 0."
    • When trying to change the brightness settings from Venus will receive the following error: "The data received from the display is incorrect." 
  • Temperature is not reading on the display.
    • Temperature locked up on display.
    • Venus reporting temperature but temperature is not fluctuating.
    • Venus may also not be reporting a temperature.
    • Setting a temperature offset does not alter temperature.
  • IDM shows communications error.

Environment

  • Product Family: Message Displays, Billboard
  • Product: GP4, DB-4200
  • Component: DMP-8065, VIP-5060
  • Control System: Venus Control Suite (VCS)

Cause

  • Firmware issue.

Resolution

  1. Power cycle display.
  2. Log into the VIP-5060.
  3. Update firmware to 2015.02.09 or newer. 
    •  Contacts Daktronics Technical Support if you require assistance.

KB ID: DD2519027


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.