Scoreboard / Clock: RC-100 Base station in server client mode, client display stays on.

Potential Symptoms

  • Client base station will not blank the display when RC-100 is powered off.
  • Client base station will turn off and then come back on after RC-100 is powered off.
  • Client base station location will only stay black after a power cycle.
  • Base station functions normally in server mode.
  • In range light on client base station is on solid when server is off.
  • Client scoreboard or DOG clock will not blank.

Environment

  • Product Family: Sports Product
  • Product: Scoreboard, BB-2101
  • Component: Base station 3.7 or 3.8 firmware
  • Control System: RC-100

Cause

  • RC-100 Client Base Station scoreboard packets continue after Server base station RF scoreboard packets halted.

Resolution

  • Use a RC-100 Client Base Station with ED-14906 Version 3.9 or greater.  Contact Daktronics Customer Support for issue verification and part recommendations.
    • United States & Canada 1-800-325-8766.
    • Outside US & Canada +1-605-697-4000.
    • Or submit a Service Request form from Daktronics Support and reference this article.

For Temporary Operation

For Basketball:

Option #1:

  • Turn power to the client basketball scoreboard off.

Option #2:

  1. Clear the scoreboard of information before turning the RC-100 Handheld off.
  2. Press "Alt" then "New Game".  Doing this will make it easier to clear/blank the scoreboard because the Bonus and Possession indicators will be blank.
  3. Press "Edit".
  4. Press "Set Time"
  5. Press "Clear".
  6. Press "Enter".
  7. Repeat steps 3-6 for each piece of data on the scoreboard until the scoreboard is blank.
  8. Power the RC-100 Handheld off.

For Play Clock:

Option #1:

  • Turn power to the Play Clocks off.
    • This is a good opportunity to remind the customer this is a best practice for outdoor scoreboards.

Option #2:

  • Clear the scoreboard of information before turning the RC-100 Handheld off.
  • Press the "Stop" key to stop the time from counting.
  • Press "Edit".
  • Press "Set Time".
  • Press "Clear".
  • Press "Enter".
  • Power the RC-100 Handheld off.

KB ID: DD3453659


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.