Show Control System: How do I trigger active and inactive processor from a button?

Topic

  • Active and inactive scripting for DI-6000, VP-6000, and VIP-5160? (advanced scripting method)
  • Venus script for active and inactive scripting
  • Display Studio button to trigger Venus Control Suite scripts
  • Show Control's Display Studio script buttons
The active 6000 processor can be verified and changed in the Service Configuration.  However for quick changes in a live event settings, it is helpful to have a script button to make this change. 
Versions after  Show Control 2.13, do not require advanced scripting.  See: Show Control System: How do I switch between active and inactive VP/DI-6000 via scripting?

Environment

  • Product: DI-6000, VP-6000, VIP-5160, Show Control System Advance Scripting, Venus Control Suite version 0.08.1058 or above
  • Components: VP/DI-6000 advanced scripting
  • Control System:

Steps

Make sure ERTD to Fusion Scripting has been set up.

Also verify that the Display Devices have been designated as Primary and Backup via the Device Set buttons. 

  1. Log in to your VENUS software
  2. Navigate to the Scripts tab
  3. Select Add New to begin building the VCS script that the display studio button will trigger
    1.png
  4. Give the script a Title such as Fascia to Backup, then under the command parameters select Activate Primary or Backup Devices and then select Save
    2.png
  5. After saving, you'll need to select the appropriate device that this script will be controlling. To do this, click the Edit button underneath Displays, and then select the correct device and choose Save
    3.png
  6. To finish the script, choose if the script is activating the Primary Devices or the Backup Devices, then select Save

Create a Script button in Display Studio.

  • Right click, select New button.
  • Add Line
  • System Control
  • Advanced
  • Select Play or if available, Run Fusion Script
    6.png
  • Configure ERTD portion of the scripting line
    • Protocol: UDP/IP (Default setting)
    • Address: 255.255.255.255 (Default setting)
    • Port: 27000 (to match Data Server configuration or Venus Control Suite: Data Package)
    • Sign Number: Match sign used in Data Server or Venus Control Suite: Data Package.
    • File: Match Fusion script name. (ex: Fascia to Backup)
      7.png

*Also see: 6000 Processor: How do I switch primary to backup via Venus Control Suite  (manual switching)

KB ID: DD3356926


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.

The above disclaimer applies to any property damage, equipment failure, liability, infringement, or personal injury claim arising out of or in any way related to your use or application of the content, whether such claim is for breach of contract, tort, negligence or any other cause of action.