DISCLAIMER: Use of this content may void the equipment warranty, please read this DISCLAIMER prior to performing any service of the equipment.

Venus hangs and needs to be forced closed, fusion service not running and will not start.

Symptoms

  • When launching Venus 1500, it will show Starting Fusion Service...but it just hangs there without generating an error or UN/PW prompt.

  • The Daktronics Fusion Service will not start and keep receiving the following error:

    • The Daktronics Fusion service on Local Computer started and then stopped. Some services stop automatically if they are not in use by other services or programs.
    • services.jpg

Environment

  • Venus 1500 V4.18 or greater

  • Daktronics Fusion

Cause

  • Daktronics Fusion became corrupted.

Resolution

  1. Run a repair on Daktronics Fusion.
  2. Restart Daktronics Fusion service manually.

If issue still persists, See Article: Receiving Error 1920- Service Daktronics Fusion (Daktronics-Fusion) failed to start- Verify that you have sufficient privileges, DD2535149.

KB ID: DD2898006