Football; DSTI and display controllers are not receiving RTD while TeraTerm monitor at baud 9600 shows RTD

​Symptoms

  • DSTI and display controllers are not receiving RTD for Football.
  • No changes to DSTI or other programs.
  • TeraTerm monitor at baud 9600 shows RTD.

Environment

  • All Sport 5000
  • DSTI
  • V7000

Cause

  • Using All Sport code 6604 which outputs at a baud of 9600 instead of 19200.

Resolution

  • Reference site drawings to verify if they are to use code 6611 for custom fixed digit displays or standard code 6601.  Both output at 19200 baud.​​