Troubleshooting IDM - Communication Failure Event on Module

Environment

  • Product Family: Billboard
  • Products: AF-2014, DB-1000, DB-2000, DB-3000, DB-4000, DB-4100, DB-4200, DB-5000, DB-6000, DB-6400
  • Component: PL5x module, power supply, ribbon cable
  • Control System: IDM

Troubleshooting Steps

Remote Troubleshooting Steps

  •  This issue cannot be addressed remotely.

Onsite Troubleshooting Steps

DB-1000 - DB-3000

  1. Is module(s) blank?
    • If yes, proceed to Step 2.
    • If no, skip ahead to Step 8.
  2.  Verify module(s) is receiving proper voltage.
    • If receiving proper voltage, skip ahead to Step 8.
    • If not receiving proper voltage, proceed to Step 3.
  3. Are the modules on the same power supply as the blank module(s) receiving power?
  4. Is power supply receiving proper voltage? (Typically 120 VAC, +/-5%)
  5. Test voltage at the breaker that supplies power to the affected area/module.
    • If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, proceed to Step 6.
  6. Test voltage at the power entrance on the sign.
    • If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, proceed to Step 7.
  7. Test voltage at main power entrance to display.
    • If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
  8. Move the ribbon cable connecting the last unaffected module and the first affected module to a new location. Does the issue follow?
  9. Move the affected module (or first affected module in that row if multiple modules in a row are impacted) to a new location. Does the issue follow?
  10. Move the last unaffected module in the row to a new location. Does the issue follow?

DB-4100

  1. Is module(s) blank?
  2. Verify correct voltage is being received at the power supply for the module. (Typically 120 VAC +/- 5%)
    • If voltage is correct, skip ahead to Step 6.
    • If voltage is incorrect, proceed to Step 3.
  3. Test voltage at the breaker that supplies power to the affected area/module.
    • If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, proceed to Step 4.
  4. Test voltage at the power entrance on the sign.
    • If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, proceed to Step 5.
  5. Test voltage at main power entrance to display.
    • If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance
    • If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
  6. Is the green indicator light lit on the power supply?
  7. Complete a self-test on the module, note error on toe tag and return for repair. Refer to How to perform a self test on a PL5x series module, DD2045934 for instruction.

 DB-4200, DB-5000, DB-6000, DB-6400

  1. Is module(s) blank?
  2. Verify correct voltage is being received at the power supply for the module. (Typically 120 VAC +/- 5%)
    • If voltage is correct, skip ahead to Step 6.
    • If voltage is incorrect, proceed to Step 3.
  3. Test voltage at the breaker that supplies power to the affected area/module.
    • If voltage is correct, you will need to ensure continuity of wiring between breaker and power supply. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, proceed to Step 4.
  4. Test voltage at the power entrance on the sign.
    • If voltage is correct, you will need to ensure continuity of wiring between power entrance and breaker. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, proceed to Step 5.
  5. Test voltage at main power entrance to display.
    • If voltage is correct, you will need to ensure continuity of wiring between power entrance on sign and main power entrance to display. Contact Daktronics or your service provider for assistance.
    • If voltage is incorrect or absent, issue is likely with incoming electrical service. Contact your power company/utilities provider.
  6. Is the green indicator light lit on the power supply?
  7. Complete a self-test on the module, note error on toe tag and return for repair. Refer to How to perform a self test on a PL5x series module, DD2045934 for instruction.

KB ID: DD3432407